Type JY06
Water cooling system hose for conveying purified water of the internal reduction electric furnace with a voltage of 6 KV
Applications:
it is suitable for conveying purified water through cable in induction electric furnace water cooling system with voltage 6KV. High insulation, wear-resisting and anti-aging.
Construction:
Tube: black smooth high insulation EPDM synthetic rubber.
Reinforcement: high strength polyester fiber.
Cover: green or black, high insulation EPDM synthetic rubber. Smooth for ID≤1", fabric impression for ID>1”.
Electrical resistance: high insulation, excellent low leakage current. The leakage current was less than 20 Micro Amp at 6KV DC/AC voltage.
Temperature range: -40 °C +120 °C
Environmental standards: EU pahs-2, REACH, ROHS directive.
Technical standard: HG/T2184, CJAN
Part no. |
ID |
OD |
Bending radius |
Work pressure |
Bursting pressure |
Weight |
Length |
|
inch |
mm |
mm |
mm |
PSI |
PSI |
kg/m |
m |
|
JY06013 |
1/2" |
12.7 |
21 |
100 |
200 |
800 |
0.31 |
100 |
JY06016 |
5/8" |
15.9 |
24 |
120 |
200 |
800 |
0.35 |
60 |
JY06019 |
3/4" |
19.0 |
28 |
150 |
200 |
800 |
0.46 |
60 |
JY06022 |
7/8" |
22.2 |
32.2 |
170 |
200 |
800 |
0.58 |
60 |
JY06025 |
1" |
25.4 |
36.8 |
200 |
200 |
800 |
0.76 |
60 |
JY06032 |
1-1/4" |
31.8 |
44.6 |
250 |
200 |
800 |
1.1 |
40 |
JY06038 |
1-1/2" |
38.1 |
52 |
300 |
200 |
800 |
1.38 |
40 |
JY06042 |
42mm |
42.0 |
56 |
336 |
200 |
800 |
1.46 |
40 |
JY06045 |
45mm |
44.5 |
59 |
360 |
200 |
800 |
1.6 |
40 |
JY06050 |
2" |
50.8 |
66 |
400 |
200 |
800 |
1.9 |
40 |
JY06063 |
2-1/2" |
63.5 |
79.5 |
500 |
200 |
800 |
2.5 |
40 |
JY06076 |
3" |
76.2 |
92.2 |
600 |
150 |
800 |
3.2 |
40 |
We will contact you within 24 hours.